BackupGenerators.com offers portable, commercial, home, diesel, Alton, Honeywell, Coleman, Powermate, Champion, electric, propane, gas, and Honda generators.
BackupGenerators.com
1-800-540-1695 ext.407     My Account   Customer Service   Shopping Cart
McAfee SECURE sites help keep you safe from identity theft, credit card fraud, spyware, spam, viruses and online scams

 

Chat Button
 
  Customer Service Rating by LivePerson


Real Customer Testimonials:

I just had to tell someone that I have not seen such excellent customer service that your company provides in a long time. - Debbie Lyon


Great web site, very easy to use...I am in the e-commerce business and am not easily impressed with web design and internet shopping! I am impressed. Great prices! Thank you! - Brian

- View all Customer Testimonials

- submit your comments here

 
Home > Generator Accessories > Transfer Switches >

Share |

Tell A Friend

GenTran ATS2001D OVATION 200/125 Amp Indoor Load Center Automatic Transfer Switch - NEMA 1, 30kW

Item #: ATS2001D
Availability: In Stock - Usually Ships in 4-6 Weeks

There are no reviews yet.
Write a review


Your Price: $974.95
Free Shipping
View In-Home Delivery Rates
Quantity:   

30 Day Money Back Guarantee Price Match Guarantee

OVATION Indoor Load Center Automatic Transfer Switch

Ovation Series Automatic Transfer Switch Model ATS2001D features 200 amp Utility and 125 amp Generator mains mechanically interlocked and housed in a NEMA 1 service entrance-rated load center. Accommodates up to 38 household circuits and generators up to 30 kW. This model is ideal for installation in new construction as the main load center in a home or business, but can also be installed in a retrofit application behind an existing load center (for example with a 400 amp service where one 200 amp panel would be for non-essential circuits and this panel would house all emergency circuits). NEMA 1 cabinet can be flush or surface mounted indoors. Compatible with virtually any stationary generator up to 30 kW. Includes 22,000 AIC rated mains. Does not include subfeed lugs to support downstream panels. (If you wish to feed a downstream panel, we recommend that you install a 2-pole 100 amp breaker and a 100 amp panel downstream. This is the least expensive way to do this.)

Accepts interchangeable type branch circuit breakers from Siemens, Square D (HOM), Cutler-Hammer (BR) and GE (THQL). Also accepts Arc fault, GFCI and Surge Suppression breakers. Up to three optional PowerPause™ Load Management modules can be added to manage up to 6 circuits to help avoid generator overloading while allowing you to run larger appliances when generator capacity is available. Programmable exerciser can be set to test generator every 0, 7, 14 or 28 days with or without load. OR the "0" exercise option may be selected if you wish to use the interval set by the generator manufacturer.

GenTran OVATION Indoor Load Center Automatic Transfer Switch ATS2001D Features:

  • Programmable exerciser can be set to test generator every 0, 7, 14 or 28 days with or without load
  • Accepts interchangeable type branch circuit breakers
  • Compatible with virtually any stationary generator up to 30 kW
  • Accommodates up to 38 household circuits and generators up to 30 kW
  • Includes ATSRK (Relay Kit) required for connection with most stationary generators for signaling between the generator and transfer switch
  • Combines a service-entrance rated load center with and automatic transfer switch for faster, simplified installation and reduced labor costs
  • All models are Service Entrance rated at no additional cost
  • Can be installed as the main load center OR a subpanel - Ideal for new construction or retrofits
  • Compatible with virtually ANY stationary generator up to 50 kW (See Support section for wiring diagrams for popular generator brands)
  • Listed with interchangeable type branch circuit breakers from Siemens, Square D (HOM), Cutler-Hammer (BR) and GE (THQL)
  • User interface with LED indicators standard on all models
  • Programmable exercise intervals - from 0, 7, 14, 28 days (with or without load) to maintain a healthy generator and significantly reduce fuel costs over time
  • Available in 100 amp and 200 amp configurations, in indoor and outdoor enclosures
  • Model ATS2002R includes subfeed lugs to easily support additional panels
  • Adjustable generator start-up delay from 5 seconds to 60 minutes, in 15 minute increments, to comply with certain ordinances.
  • Microprocessor-controlled, open transition, circuit breaker-based switching with manual override
  • Optional PowerPause Load Management modules and Relay Boxes available
  • For single phase (125/250V) 60 hZ or 50 Hz applications
  • UL Listed
Model Specifications
Model Number: ATS2001D
Manufacturer: GenTran
# Circuits (1 Pole): 38
Enclosure Type: NEMA 1
Generator Main: 125 A, 2 Pole
Utility Main: 200 A, 2 Pole
Max Amps @ 240V: 125 Amps
Max Generator Size: Up to 30kW
Voltage: 120/240 VAC
Frequency/Phases: 60 Hz, 1 Phase
UTIL AIC Rating: 22K
Dimensions
Dimensions: 14.31"W x 3.93"D x 42"H
Weight: 46 lbs.