The GSW Series provides the most professional way to fulfill power requirements with highest reliability and excellent performance.
Generator Capabilities:
- Rated prime power (PRP): 45 kW/45 kVA
- Emer Power (LTP): 50 kW/50 kVA
- Voltage: 240, 120V
- Frequency: 60 Hz
- Power factor: 1 cosPhi
Engine Specifications:
- Engine manufacturer: Perkins
- Model: 1104D-E44TG
- Fuel: Diesel
- Exhaust emission: EPA Tier 3
- Cooling system: Water
- Nominal operating speed: 1800 rpm
- Displacement: 269.1 cu inches
- Number of cylinders and disposition: 4, inline
- Aspiration: Turbo
- Power (PRP): 87 bhp
- Power (LTP): 97 bhp
- Fuel consumption (III) at 75% PRP: 3.59 gal/h
- Fuel consumption (III) at 100% PRP: 4.81 gal/h
- Specific fuel consumption at PRP: 0.383 lb/hph
- Engine governor: Mechanical
Alternator Specifications:
- Alternator manufacturer: Stamford
- Model: UCI 224 E
- Power at 27°C (480 V): 79 kWE/99 kVA
- Power at 27°C (208 V): 71 kWE/89 kVA
- Power at 27°C (240 V): 45 kWE/56 kVA
- Insulation class: H
- Protection grade: IP 23
- Voltage regulation system: Electronic, 1,5%
Consumption:
- Fuel tank capacity: 91.93 gal
- Autonomy (III) at 75% PRP: 25.5 h
- Autonomy (III) at 100% PRP: 19.1 h
Automatic control panel (ACP):
Description Automatic control panel mounted on the genset, complete with digital control unit AC01 for monitoring, control and protection of the generating set.
- Generator set voltage (3 phases)
- Mains voltage
- Generator set frequency
- Generator set current (3 phases)
- Battery voltage
- Power (kW - kVA - kVAr)
- Power factor
- Hour counter
- Engine rpm
- Fuel level (%)
- Engine temperature
Automatic control panel (ACP): commands and other features
- Setting: Automatic test
- Setting: Automatic starting
- Setting: Engine locked
- Setting: Mains contactor forced
- Setting: Manual start
- Setting: Genset contactor forced
- Emergency stop button
- Remote start capable
- Acoustic alarm
- Integrated battery charger
Automatic control panel (ACP): protections with alarm
- Engine protection: low fuel level
- Engine protection: low oil pressure
- Engine protection: high engine temperature
- Genset protection: start failure
- Genset protection: under/over voltage
- Genset protection: under/over frequency
- Genset protection: under/over battery voltage
- Genset protection: battery charge failure
- Genset protection: overload
Automatic control panel (ACP): protections with shutdown
- Circuit bracker and differential protection Optional
- Engine protection: low fuel level
- Engine protection: high engine temperature
- Engine protection: low oil pressure
- Genset protection: under/over voltage
- Genset protection: overload
- Genset protection: under/over battery voltage
- Genset protection: battery charge failure
Automatic control panel (ACP): output features
- Power cable connected to terminals board (external)
- Main lugs
|