The GRW Series is designed for the most demanding power in general applications, ideal for rental operators. It features a modern design, low noise level and versatile accessories.
Generator Capabilities:
- Rated prime power (PRP): 13 kVA
- Emer Power (LTP): 15 kVA
- Voltage: 240, 120V
- Frequency: 60 Hz
- Power factor: 1 cosPhi
Engine Specifications:
- Engine manufacturer: Yanmar
- Model: 3TNV88
- Fuel: Diesel
- Exhaust emission: EPA Tier 3
- Cooling system: Water
- Nominal operating speed: 1800 rpm
- Displacement: 100.2 cu inches
- Number of cylinders and disposition: 3, inline
- Aspiration: Natural
- Power (PRP): 22 bhp
- Power (LTP): 24 bhp
- Fuel consumption (III) at 75% PRP: 0.90 gal/h
- Fuel consumption (III) at 100% PRP: 1.19 gal/h
- Specific fuel consumption at PRP: 0.397 lb/hph
- Engine governor: Mechanical
Alternator Specifications:
- Alternator manufacturer: Stamford
- Model: BCI 184E
- Power at 27°C (240 V): 14 kWE/14 kVA
- Insulation class: H
- Protection grade: IP 23
- Voltage regulation system: Electronic, 1,5%
Consumption:
- Fuel tank capacity: 21 gal
- Autonomy (III) at 75% PRP: 22 h
- Autonomy (III) at 100% PRP: 16.5 h
Manual control panel (MCP)
Description Manual control panel mounted on the genset, with analogue instrumentation, and protected through door with lockable handle
Manual control panel (MCP): analogue instrumentation
- Voltmeter
- Ammeter
- Frequency meter
- Hour counter
- Fuel level indicator
- Oil pressure
- Engine temperature
Manual control panel (MCP): commands and other features
- Start/stop selector switch with key
- Emergency stop button
- Potentiometer for adjusting the output voltage
- Six wire multipin connector for remote start/stop signal and battery charger feeding
Manual control panel (MCP): protections with alarm
- Engine protection: low fuel level
- Engine protection: low oil pressure
- Engine protection: high engine temperature
- Genset protection: battery charge failure
Manual control panel (MCP): protections with shutdown
- Circuit breaker
- Engine protection: low fuel level
- Engine protection: high engine temperature
- Engine protection: low oil pressure
- Genset protection: battery charge failure
Manual control panel (MCP): output features
- 2 x 120V 20A 2P + T NEMA (duplex with GFCI)
- 1 x 240/120V 50A 2P + T NEMA (twistlock)
- Main lugs
- Power cable connected to terminals board (external)
Genset features:
- VSS - Voltage selector switch (Rotary switch to reconnect the alternator for different output voltages from three phase to single phase) - star (III) / parallel star (III) / zig-zag (II)
- KRT - Rental kit (complete with: battery switch; Fuel filter water separator; Three way valve; Earth rod)
Genset supplements (to be installed during manufacturing process)
- EFT - Extended capacity fuel tank (Capable to increase genset autonomy from 16-20 hours)
- TRL - Road trailer
|